Science

Methods › A. Flow rules

Percent-of-flow presumptive standard

Also called: Sustainability boundary approach

Not yet reviewed AI-drafted from the references listed · Reviewed by: not yet reviewed · Review date: not yet reviewed

Drafted with AI from the references listed (Claude, by Anthropic). A person has not checked it yet. Confirm details against the original references before relying on it.

What it is

A rule that limits how far daily flows may depart from natural flows, expressed as a percentage, instead of fixing a minimum volume. Because the limit is a share of the flow actually occurring, the natural pattern of high and low flows, and of wet and dry years, is kept. Richter et al. (2011) proposed that alterations within 10% of natural daily flow give high protection, 10-20% moderate protection, and more than 20% a growing risk of moderate to major change.

How it works

  1. Build the natural (unaltered) daily hydrograph for the site
  2. Set the allowable percentage departure (depletion or augmentation) from natural flow, which may vary through the year
  3. For the presumptive standard, use within 10% for high protection or 10-20% for moderate protection
  4. Allow water use only within that band of daily natural flow
  5. Optionally, add a minimum 'hands-off' flow during low-flow periods below which all abstraction stops; the authors describe this as an additional consideration.

What you get

Output
Allowable % departure
Kind of answer
One answer: it recommends a single value or flow regime for one objective.

What it needs

Data needs
Low
Effort
Desktop
Resolution
Low
Typical team and time at this resolution
ItemLow resolution
Specialists1-2 people
Environmental flow practitioners1 person
Duration1-2 months
Total effort5-12 person-days

Typical figures from IFC (2018), Table 5 (p. 60), for one hydropower-project assessment, after King and Brown (2015). Estimates only: travel and stakeholder liaison are not included.

Good for, not suited to

Good for
Interim or regional protection where detailed studies are not yet available; keeps the natural flow pattern and is easy to understand and apply.
Not suited to
Hydropeaking operations, where daily flows may not be enough and hourly guidelines may be needed; on its own it may not protect very low flows without an added hands-off flow.

Where it came from

Origin
Richter 2010 (SBA) and Richter et al. 2011/2012 (presumptive standard), USA; interim protection of daily flows until more detailed (e.g. ELOHA) studies are done

Research on this method

Where it was defined

How to run it

Reviews, tests and criticism

Studies that apply it

Other documents cited in the register

Guidance, reports and method documents from the methods register. Most are not in the papers index.

Papers are picked from the papers index, where records are found and classified by AI from titles and abstracts. Check the paper itself before relying on it.

About this page

Drafted with AI from the references listed (Claude, by Anthropic). A person has not checked it yet. Confirm details against the original references before relying on it.

Described from the references listed, with key statements matched by script to quoted text from saved copies. Record AM-0003, methods register v1.12. Spotted an error? hello@environmentalflows.com

All methods